KBI 311333 Issue Addressed: Performance Rule Is Reported Broken For One Instance And Wrongly Auto-Corrected For Another Instance

Version

Argent Advanced Technology 3.1A-1601-A

Date

Monday, 4 January 2016

Summary

Event can be wrongly corrected for Performance Rule when following conditions are true:

  1. Option ‘Fire Separate Events For Each Performance Instance’ is checked
  2. Wildcards are used for performance counter instances
  3. Rule is broken for some instances and not for other instances

When auto-correction is enabled in Relator, Event can be fired for an instance that breaks the Rule, and immediately auto-corrected, but wrongly for another instance

It can cause the Event being fired each time when the Relator is executed

The issue has been addressed in Argent AT 3.1A-1601-C

Technical Background

The issue is caused by coding error

Resolution

Upgrade to Argent AT 3.1A-1601-C or later

For customer who cannot upgrade immediately, he should turn off the option ‘Fire Separate Events For Each Performance Instance’