KBI 311738 Issue Addressed: Always Read No New VMware Events
Version
Argent Advanced Technology 5.1A-1901-B or below
Date
Monday, 18 March 2019
Summary
Argent for Compliance can monitor and archive VMware Events
However, when Argent Advanced Technology Engine runs VMware Event Log Rule, it always read from current time
As a result, no new Events would be read unless there is major time difference between vCenter and Argent Advanced Technology Engine
The issue has been addressed in Argent Advanced Technology 5.1A-1901-C
Technical Background
The issue is caused by coding error
Resolution
Upgrade to Argent Advanced Technology 5.1A-1901-C or above