KBI 220739 Unmatched Field Length For Column Ruletype

Version

Argent Console 8.0A-0707-D

Date

5 September 2007

Summary

When upgrading from 8.0A-0707-C to 8.0A-0707-D the installer may report an error during the Database Integrity Check:

— ERROR — Unmatched field length for column ‘ruletype’ (16 vs. 32 bytes)

This does not appear to affect the further operations of the installer, nor impede the Customer’s ability to launch the Argent Management Console.

Technical Background

N/A

Resolution

To resolve this issue, open the Argent Management Console.

Select Tools -> Database Integrity Checker -> Argent Console.

Click on the Load SQL Script button and select Upgrade_MSSSQL_0701-0704.sql.

Click on the Run Script button.

If any errors are produced, select Yes button to continue execution of script until you see:

Script is executed successfully.

Click the Start button to re-run the Database Integrity Check to confirm table structure is correct.