KBI 311594 Exclude Logical Disk From Disk Space Monitoring
Version
Argent Advanced Technology – All Versions
Date
Tuesday, 12 December 2017
Summary
In certain situations it is required to exclude a Logical Disk from disk space monitoring on a particular Windows server, while not excluding that drive from other server Nodes monitored
This is possible using the field Drives Not To Monitor in the “CMDB-X – Node Properties – Logical Drives”
Technical Background
In this example the disk drives E: and F: are broken and both are required for exclusion from monitoring
![](https://help.argent.com/wp-content/uploads/ARGENT_KBI_311594_01.jpg)
From the CMDB-X
![](https://help.argent.com/wp-content/uploads/ARGENT_KBI_311594_02.jpg)
Add ‘E: F:’ in Drives Not To Monitor from “Node Properties – Logical Drives”
Note: Multiple drives are entered as space delimited
![](https://help.argent.com/wp-content/uploads/ARGENT_KBI_311594_03.jpg)
Retesting the Rule result shows as Not Broken and the Trace Log shows IGNORE counter
![](https://help.argent.com/wp-content/uploads/ARGENT_KBI_311594_04.jpg)
Resolution
N/A