KBI 220038 Invalid Purge Time Format
Version
All
Date
20 Apr 2001
Summary
The message Invalid Purge Time Format is generated when the registry entry holds invalid data (not hh:mm:ss):
HKEY_LOCAL_MACHINE\Software\Argent\SchedulingEngine\Rollover\Time
Technical Background
The message is generated every 30 seconds when the engine checks for rollover.
When the entry is invalid, a midnight rollover (00:00:00) is assumed.
Resolution
To correct the issue, take following steps:
- Close Job Scheduler GUI.
- Stop Job Scheduler Service.
- Open the registry and correct the key to hh:mm:ss format.