KBI 220038 Invalid Purge Time Format

Version

All

Date

20 Apr 2001

Summary

The message Invalid Purge Time Format is generated when the registry entry holds invalid data (not hh:mm:ss):

HKEY_LOCAL_MACHINE\Software\Argent\SchedulingEngine\Rollover\Time

Technical Background

The message is generated every 30 seconds when the engine checks for rollover.

When the entry is invalid, a midnight rollover (00:00:00) is assumed.

Resolution

To correct the issue, take following steps:

  1. Close Job Scheduler GUI.

  2. Stop Job Scheduler Service.

  3. Open the registry and correct the key to hh:mm:ss format.