KBI 311084 Issue Addressed: Auto Event Resolving In Argent Defender Does Not Work Sometimes
Version
Argent Advanced Technology 3.1A-1407-A or earlier
Date
Monday, 29 Sep 2014
Summary
Argent Defender TEST can be configured to resolve Events automatically
It is found that the mechanism does not work occassionally
The issue has been addressed in Argent Advanced Technology 3.1A-1407-T5
Technical Background
Argent Defender RTP session can be configured with re-run option
Due to various network issues, web logic may fail in the first run but succeed in the following run
Argent Defender Engine will fire Event for the error found in the first run, and attempt to correct the Event immediately after that
Argent Defender uses a separate worker thread to handle the slow Event firing, which needs TCP communication with Argent Console Engine
It is possible that the auto-resolving happens before the Event is actually fired
As a result, the Event will not be resolved
Resolution
Upgrade to Argent Advanced Technology 3.1A-1407-T5 or later