KBI 311318 Issue Addressed Argent Queue Engine Restarts And Jobs Are Reported As Abended In the Scheduler GUI
Version
Argent Job Scheduler 10.0 1505-A and earlier
Date
Monday, 21 September 2015
Summary
An issue has been addressed that Argent Queue Engine Restarts And Jobs Are Reported As Abended In the Scheduler GUI
Technical Background
Argent Queue Engine restarts and Jobs are reported as Abended in the Argent Job Scheduler GUI
When applications other than Argent Job Scheduler try to connect and send malicious data to the Argent Queue Engine port (default is 3135), Queue Engine may undergo a restart
Following error messages can be found in log when this issue is occurred::
09 May 2015 00:26:49.381 SRV0017 SVC_ARGENT (03268-03016) 02097 C8000_GetCore Failed: The memory length requested is invalid. Program XS_Worker.cpp, Line 2,097
09 May 2015 00:30:06.648 SRV0017 SVC_ARGENT (03268-03956) 02114 Socket error reading data field (-18): error allocating memory for receiving the data
09 May 2015 03:05:11.610 SRV0017 SVC_ARGENT (05892-02648) 00612 C8000_GetCore Failed: Error allocating 1,431,792,833 bytes by XS_Worker.cpp at 2,097
Resolution
Upgrade to Argent Job Scheduler 10.0 1509-A or later