KBI 311216 KBI Issue Addressed: Previously Cancelled Test Result Might Be Shown When Testing Relator/Rule Using Engine
Version
Argent Advanced Technology 3.1A-1504-A and earlier
Date
Tuesday, 26 May 2015
Summary
When testing Relator or Rule in Argent AT GUI, customer can chose to use specific Engine
If the previous test used the same Engine and was cancelled, the old test result might be displayed immediately
The resulting Notepad results contains the results from the previously run Relator test
The Relator test then needs to be run again in order for the Notepad to return newer results from the current test
The issue has been addressed in Argent AT 3.1A-1504-T1
Technical Background
When testing Relator or Rule using specific Engine, the asynchronous Work Orders are used for communication
When a test is cancelled, the Engine may already pass back the result Work Order
The result Work Order file is not processed because of cancelled test
As a result, it might be treated as test results for the new test
Resolution
Upgrade to Argent AT 3.1A-1504-T1 or later