KBI 310122 Exchange Power Shell Adapter Function Fails On 64-Bit Platforms
Version
Argent Extended Technology prior to version 0807-T3
Date
9 Oct 2008
Summary
When users create Relators to monitor Microsoft Exchange 2007 servers, the Power Shell error
“SYSTEM.BADIMAGEFORMATEXCEPTION: AN ATTEMPT WAS MADE TO LOAD A PROGRAM WITH AN INCORRECT FORMAT”
is generated in the Results Log of Relator testing and the Relator Trace Log.
The following are examples of the errors customers receive:
Technical Background
When the Argent Extended Technology Monitoring Engine used to monitor Microsoft Exchange 2007 is installed on a 64-bit Windows server (which includes the 64-bit version of .Net), the Argent Power Shell adapter fails to load the 32-bit ARB_Kernel.dll.
Resolution
Upgrade to Argent Extended Technology 8.0A-0807-T3 or later.